Add to Cart
Comprehensive Three-phase Protection Relay Test Set
Model: RELAYSTAR-806
The RELAYSTAR-806 is comprehensive three-phase protection relay test set and commissioning tool. It has 7 channels for output((3I + 4U), and every output channel is independent and simultaneous control of magnitude, phase angle and frequency values.
The RELAYSTAR-806 kit can be independently operated via embedded industrial PC with 8-inch LCD screen, full keyboard and mouse, no PC required. The operator also can connect RELAYSTAR-806 kit to laptop, use RELAYSTAR software running on the laptop with Windows operating system to fully control the RELAYSTAR-806 kit to complete all tests and save the test results into laptop.
Main Features
1) Universal relay test applications
2) 7-channel outputs(3I + 4U)
2) Embedded industrial PC with 8-inch LCD screen, full keyboard and mouse
3) Control and operate with or without PC
4) Independent AUX DC output
5) End to end test with in-built GPS
6) Full functional RELAYSTAR test software
7) RIO file import & export facility
8) Power system model for dynamic testing
9) Online vector display
10) Switch on to fault test(SOTF)
11) Automatic test report creation
12) Software upgrade free of charge
Technical Data
Current Generator
Setting range | 3-phase AC(L-N) | 3x0…40A |
1-phase AC(LL-LN) | 1x0…120A | |
DC(L-N) | 3x…±10A | |
Power
| 3-phase AC(L-N) | 3x300VA at 40A |
1-phase AC(LL-LN) | 1x1000VA at 120A | |
DC(L-N) | 3x120VA at 10A | |
Accuracy | AC: ±1mA(≤0.2A), ≤0.1% (0.2~40A) | |
DC: ±5mA(0~0.5A), ≤0.2% (0.5~10A) | ||
Resolution | 1mA |
Voltage Generator
Setting range | 4-phase AC(L-N) | 4x0…150V |
1-phase AC(L-L) | 1x0…300V | |
DC(L-N) | 3x…±160V | |
Power | 4-phase AC(L-N) | 4x70VA at 150V |
1-phase AC(L-L) | 1x140VA at 300V | |
DC(L-N) | 3x80VA at 160V | |
Accuracy | AC: ±2mV(0.2~2V), ≤0.1% (2~150V) | |
DC: ±10mV (0~5V), ≤0.2% (5~160V) | ||
Resolution | 1mV |
Auxiliary DC Output
Voltage range | 110V/220V(max.1.5A) |
Power | max.165VA/330VA |
Binary Inputs
Number | 8 |
Input characteristics | idle contact or potential-free contact |
Threshold characteristics | “0”:0~6V; “1”:12V~250V |
Max. measuring time | 999999.999s |
Time accuracy | ±1ms |
Time resolution | 1ms |
Binary Outputs
Number | 4 |
Type | idle contact |
Break capacity | 250VAC/0.5A, 250VDC/0.2A |
General Generators
Frequency | range: 0~1200Hz |
accuracy:<1mHz(0~65Hz),<10mHz(65~450Hz),<20mHz(450~1200Hz) | |
resolution: 0.001Hz | |
Phase | range: -360° ~+360° |
accuracy: 0.1° | |
resolution: 0.01° | |
Harmonic | superposition order: 2~24 times |
distortion: ≤0.5% |
Power Supply
Nominal input voltage | customized (AC 220V/230V/120V±10%, 1-phase) |
Nominal frequency | 50/60 Hz |
Rated current | 10A at 230V / 12A at 115V |
Connection | standard AC socket (IEC 60320) |
Miscellaneous
Weight | 18kg(39.68 lb) |
Dimensions (W x H x D, without handle) | 405×300×164mm(15.94x11.81x6.46 in) |
Connection port | 2 USB2.0 ports, 1 Ethernet port |
The Comprehensive Three-phase Protection Relay Test Set RELAYSTAR-806 is primarily designed for secondary testing of protection relays. Virtually all types protection relays defined by ANSI/IEEE can be tested. The examples of what RELAYSTAR-806 can test are shown as below table.
ANSI / IEEE No. | Device or Function Name |
2 | Time Delay Staring |
3 | Checking or Interlocking Relay |
7 | Rate-of-change Relay |
13 | Synchronous-speed Device |
15 | Speed or Frequency, Matching Device |
16 | Data Communication Device |
18 | Accelerating or Decelerating Device |
21 | Distance Relay |
24 | Volts per Hertz Relay |
25 | Synchronizing or Synchronism-check Device |
27 | Undervoltage Relay |
30 | Annunciator Relay |
32 | Directional Power Relay |
36 | Polarity or Polarizing Voltage Device |
37 | Undercurrent or Underpower Relay |
40 | Field Relay |
44 | Unit Sequence Starting Relay |
46 | Reverse-phase or Phase-balance Current Relay |
47 | Phase-sequence Voltage Relay |
48 | Incomplete Sequence Relay |
50 | Instantaneous Overcurrent or Rate of Rise Relay |
51 | AC Time Overcurrent Relay |
55 | Power Factor Relay |
59 | Overvoltage Relay |
60 | Voltage or Current Balance Relay |
62 | Time-delay Stopping or Opening Relay |
66 | Notching or Jogging Device |
67 | AC Directional Overcurrent Relay |
68 | Out-of-step or Blocking Relay |
69 | Permissive Control Device |
74 | Alarm Relay |
76 | DC Current Relay |
77 | Telemetering Device |
78 | Phase-angle Measuring Relay |
79 | AC Reclosing Relay |
81 | Frequency Relay |
82 | DC Load-measuring Reclosing Relay |
83 | Automatic Selective Control or Transfer Relay |
85 | Carrier or Pilot-wire Receiver Relay |
86 | Lockout Relay |
87 | Differential Protective Relay |
91 | Voltage Directional Relay |
92 | Voltage and Power Directional Relay |
94 | Tripping or Trip-free Relay |